Marine Fire Extinguisher • Fire Safety Equipment • Boating Safety
Fireboy Marine Fire Suppression Systems
Fireboy MA2 Series: Manual / Automatic Discharge
- Protecting vessels with engine rooms up to 1500 cubic feet.
- Total flooding system.
- On board, on guard, 24 hours a day, the safest way to combat an engine room fire.
- Automatic discharge at 175°F (79°C) with optional manual release cable.
- Available with FE-241 or HFC-227ea – both are effective Halon replacement clean agents.
- No water or powdery residue.
- Each system includes stainless steel mounting brackets, 2″ round system status indicator light, and owner’s manual / installation instructions.
- 3-Year Limited Warranty.
- USCG, Factory Mutual, and Bureau Veritas Approved.
Fireboy CG2 Series: Automatic Discharge
- Protecting vessels with engine rooms up to 1000 cubic feet.
- Total flooding system.
- On board, on guard, 24 hours a day, the safest way to combat an engine room fire.
- Automatic discharge at 175°F (79°C)
- Available with FE-241 or HFC-227ea – both are effective Halon replacement clean agents.
- No water or powdery residue.
- Each system includes stainless steel mounting brackets, 2″ round system status indicator light, and owner’s manual / installation instructions.
- 3-Year Limited Warranty.
- USCG, Factory Mutual, and Bureau Veritas Approved.
Fireboy GA Series: Large Capacity
- Designed for larger boats and yachts, engine room protection from 1501 cu. ft. to 3000 cu. ft.
- Pre-engineered, total flooding system.
- Patented two-cylinder linked system design.
- GA link allows faster and easier installation with double check-valve quick-connects.
- Custom manufactured to order.
- The 1st pre-engineered system approved by the USCG for volumes over 1500 cu. ft.
- HFC-227ea clean agent leaves not water or powdery residue.
- USCG, Factory Mutual, RINA and Bureau Veritas Approved.
- 3-Year Limited Warranty.
Fireboy FES Series Total Flooding Clean Agent Engineered System
- Protecting vessels with engine rooms up to 17,300 cubic feet / 500 cubic meter.
- No water or oily powdery residue.
- Total flooding system.
- Fireboy fire systems are specifically designed for protecting enclosures up to 17,300 cubic feet / 500 cubic meter, such as engine rooms on boats.
- FES System.
- An engineered system utilizing a fixed nozzle agent distribution network, the system is designed and installed in accordance with the IMO FSS CODE (SOLAS, IMO MSC/ Circ.1267 “Clean Agent Fire Extinguishing Systems”).
- When properly designed, the HFC-227ea fire extinguishant system will suppress surface burning fire in Class A, B, and C hazards.
- 80% of HFC-227ea fire extinguishant fire fighting effectiveness is achieved through heat absorption and 20% through direct chemical means (action of the fluorine radical on the chain reaction of a flame.
- Complete suppression using HFC-227ea fire extinguishant has the following advantages:
- The low concentration of HFC-227ea fire extinguishant required means less visual obscurity and minimal risk to personnel.
- The small quantity of agent discharged minimizes over-pressurization of the protected area.
- Maximum safety for personnel due to low toxicity.
- The ability to prevent re-ignition as long as concentration levels are maintained.
- FES System listings and approvals:
- USCG
- RINA Type Approval – IMO MSC/ Circ.848/1267
- MED – Marine Equipment Directive
- MCA
- HFC-227ea (DuPont™ FM-200®) fire extinguishant listings and approvals:
- Maritime & Coastguard Agency (MCA)
- RINA
- Factory Mutual (FM)
- Underwriters Laboratories (UL)
- NFPA 2001
- EPA SNAP
- Australian Industrial Chemicals Notification
- German Institute for Environmental Hygiene and Medicine
Kidde Clean Agent Fire Suppression System
Kidde Marine ECS FM-200 Fire Suppression System
The Kidde ECS Series Marine Suppression System is an engineered system employing clean, fast, people-safe FM-200 gaseous agent. The system offers versatile waterless protection for small, medium and large shipboard applications including machinery spaces and other Class B fire hazards. The system provides flexible location of agent storage cylinders. Compact design reduces weight and maximizes available installation space.
Marine Approvals:
- US Coast Guard
- American Bureau of Shipping (ABS)
- Maritime and Coastguard Agency (UK)
- Det Norske Veritas (DNV)
- Australian Maritime Safety Administration
- Swedish Maritime Administration
- Norwegian Maritime Directorate
- New Zealand Maritime Safety Administration
Kidde Marine ADS FM-200 System
The Kidde FM-200 Marine ADS Series Engineered Fire Suppression System is a clean agent suppression system intended for use in total flooding applications on marine vessels. The system is USCG approval and UL listed. The Kidde FM-200 Marine ADS System is used to suppress fires in specific hazards or equipment when an electrically non-conductive agent is required, where agent cleanup creates a problem, when extinguishing capability with a low weight is desired and where the hazard is normally occupied. Kidde FM-200 Marine ADS Systems are intended to protect spaces containing the following hazards:
- Class A: Surface type fires; wood or other cellulose-type material
- Class B: Flammable liquids
- Class C: Energized electrical equipment
Marine Approvals:
- US Coast Guard (Certificate of Approval)
- Underwriters Laboratories, Inc. (UL2166)
- Underwriters Laboratories of Canada (ULC/ORD – 1254C.6)
- Classification Society approvals pending
Kidde Marine 3M Novec 1230 Fire Suppression System
Kidde Engineered Marine Fire Suppression System designed for use with 3M Novec 1230 Fire Protection Fluid is engineered to provide clean, fast, people-safe protection for applications requiring a “green” solution to fire suppression. The system includes detectors, a control unit, agent storage cylinders, piping and discharge nozzles. The system is computer calculated to provide system discharge within 10 seconds.
Marine Approvals:
In addition to the numerous land-based listings and approvals Kidde Marine Engineered Systems Designed for Use with 3M Novec 1230 fluid hold, approval and certification has been received from numerous maritime regulatory bodies, including:
- US Coast Guard
- Transport Canada (TC)
- Lloyd’s Register of Shipping (LR)
Kidde Marine Carbon Dioxide Fire Suppression System
kidde co2 fire suppression system
The Kidde Carbon Dioxide Fire Suppression System is an engineered system available in three application configurations: total flooding (for unoccupied areas), local application or hand-hose line. System includes detectors, a control unit, agent storage cylinders, piping and discharge nozzles. Gaseous carbon dioxide rapidly suppresses fire by a combination of cooling and oxygen displacement. Discharge duration and agent flow rates are customized for the individual application.
Kidde Marine WHDR Wet Chemical System (Galley)
The Kidde WHDR System is a pre-engineered fire protection system designed for the protection of commercial cooking appliances and ventilation equipment. The WHDR System provides total extinguishment and prevention of re-flash in protected galley areas. The WHDR System is UL Listed for operating in a temperature range of 0°F (-18°C) to 120°F (40°C) making it ideal for the extreme environments vessels face around the world.
Kidde manufactures its products to the most stringent testing standards and is an ISO 9001 manufacturing facility. The Kidde WHDR System provides convenient on-board recharge capabilities to minimize business interruption in the event of a discharge. Individual agent containers are pre-measured and shipped in handy storage containers.
Marine Approvals:
The Kidde WHDR System complies with the requirements of the following agencies:
- American Bureau of Shipping (Type Approval)
- Lloyd’s Register of Shipping (Type Approval)
- Det Norske Veritas (Type Approval)
- ISO 15371
- Underwriters Laboratories, Inc. (UL300)
- Underwriters Laboratories of Canada (ULC/ORD – 1254C.6)
- US Public Health Service
Kidde Marine SBS System
The Kidde Marine SBS System is designed to protect yachts and commercial vessels of all types. Kidde Marine offers two basic system configurations of the SBS System: the Sentinel and Sentinel PRO. Both component packages can be customized to provide the features and functionality required for the specific application.
Both the Sentinel and the Sentinel PRO packages are high-performance fire suppression systems that optimize 1) fire detection; 2) fire suppression agent distribution; and 3) system cylinder placement. Choose the Sentinel for smaller protected spaces where system simplicity is desired or choose the Sentinel PRO for vessels with more complex requirements. Both packages feature engineered system capabilities with modular system ease.
The SBS System is a “total-flood” fire suppression system that discharges a gaseous clean agent into the protected space. The agent is stored under pressure as a liquid and released into the space as a gas. The gas combines with the air in the space to create an atmosphere which rapidly suppresses combustion. The SBS System is suitable for both gasoline and diesel powered vessels.
Sea-Fire Marine Fire Suppression System
Sea-Fire H-Series Engineered Systems
H-Series feature enviromentally responsible FM-200 fire suppressant. Systems are designed and approved to protect enclosed spaces from 1500 c.f. ( m3) up to 17,500 c.f. ( 500m3). Systems are IMO/SOLAS tested & approved – USCG, RINA, DNV, Lloyds/MCA, GL, Transport Canada, Australia & New Zealand Maritme. Applications include workboats, transport vessels, large scale pleasure yachts, and onshore/offshore marine applications. Each custom designed engineereed fire suppression system according to the authority having jurisdiction (AHJ) and provide for Manual, Automatic & Manual with time delays or electrical release options, For volumes over 17500 c.f. submittal of system design to the AHJ is required.
Sea-Fire Pre-Engineered FM-200 FG, FD & MD System
Sea-Fire “FM200” FG, FD & MD extinguishing systems are designed to induce a minimum atmospheric concentration of 8.7% within the protected compartment. FG models are suitable for use from 0 degrees F (-18 degrees C) to 130 degrees F (54 degrees C), FD & MD models from 20 degrees F (-7 degrees C) to 130 degrees F (54 degrees C). FG & FD models operate automatically “A” through heat activation. However systems with an “M” designation contain a manual capability feature. That is, the captain or authorized personnel has the option of pulling a discharge cable which activates the fire system. MD models are manual only systems.
ABS flag rina flag dnv flag germanischer lloyd flag lloyds register flag
DIDN’T FIND WHAT YOU’RE LOOKING FOR? NO PROBLEM!
Give us a call at (954) 973-8054 or visit our location (directions here) and we will be more than happy to set you up with an industry specialist to help guide you in the right direction. Our product and service specialists are waiting to hear from you.